Mge Ups Battery Driver
It is fully supported by NUT UPS Tools 2.6.3 on Unbuntu 12.04 with the usbhid-ups driver. The vendor has a Linux commitment — they provide their own Intelligent Power Protector (IPP) software for Linux (I didn’t use it, choosing NUT instead). Readily available replacement battery. Other users report it works with Ubuntu 12.04. Download MGE UPS SYSTEMS Drivers (English) for Windows to battery driver.
Eaton Corporation’s acquisition of MGE Office Protection Systems (November 2007) created a larger, stronger power quality business with a globally enhanced competitive position and a wide range of single-phase UPS products, expertise and resources. Through the acquisition, Eaton has secured its position as the world’s second-largest manufacturer and supplier of single-phase UPS products, delivering even greater value to its customers. In fact, the majority of Fortune 500 companies relies on Eaton for its power protection, distribution and management solutions.
MGE Office Protection Systems products are a part of the Pulsar Series of solutions offered by Eaton. The products are designed and manufactured to offer secured power and data protection conditioners for enterprises, small business and homes, with a range of uninterruptible power systems, power conditioners and surge suppressors.
Documentation and replacement UPS products
Visit our legacy products page to download manuals and to see which current Eaton UPS is the most likely replacement model.Name
mge-shut - Driver for SHUT Protocol UPS equipment
Synopsis
mge-shut -h
mge-shut -a UPS_NAME [OPTIONS]
NoteThis man page only documents the hardware-specific features of the mge-shut driver. For information about the core driver, seenutupsdrv(8).
Supported Hardware
mge-shut supports all recent Eaton, MGE and Dell UPS models which use the SHUT (Serial HID UPS Transfer) protocol.
Older MGE models, such as Pulsar ESV+, Pulsar EX and Pulsar ES+, use the U-Talk protocol and should use the mge-utalk driver.
Extra Arguments
This driver also supports the following optional settings:
lowbatt=num
Set the low battery warning threshold at which shutdown is initiated by upsmon(8).The factory default value is 30 (in percent), and can be settable depending on the exact model.
Mge Ups Battery Driver 18v
The default value is 20 (in seconds). Usually this must be lower than ondelay, but the driver will not warn you upon startup if itisn't.
The default value is 30 (in seconds). Usually this must be greater than offdelay, but the driver will not warn you upon startup if it isn't.Some UPS'es will restart no matter what, even if the power is (still) out at the moment this timer elapses. In that case, you could try if setting ondelay =-1 in ups.conf helps.
ondelay parameter was set in ten seconds unit in the legacy mge-shut driver ( 3 for 30 seconds) . It is now set in seconds ( 30 for 30 seconds). Make sure youuse the correct unit in your configuration.
This argument is ignored. It is only here for backward compatibility.
Known Issues
Repetitive timeout and staleness
Some models tends to be unresponsive with the default polling frequency. The result is that you have some 'data stale' errors in your system log.In this case, simply modify the general parameter 'pollinterval' to a higher value (like 10 for 10 seconds). This should solve the issue.
Using notification=3 might also help.
Author
Arnaud Quette
See Also
The core driver
Mge Ups Battery Driver
- The NUT (Network UPS Tools) home page: http://www.networkupstools.org/